IDFA / IDF Refrigerant:
 |
Refrigerant Air Dryer IDFA Series Small - 3E, 4E, 6E, 8E, 11E, 15E, 22E, 37E, 55E, 75E |
|
Model |
IDFA3E -23 |
IDFA4E -23 |
IDFA6E -23 |
IDFA8E -23 |
IDFA11E -23 |
IDFA15E -23 |
IDFA22E -23 |
IDFA37E -23 |
IDFA55E -23 |
IDFA75E -23 |
Rated Condition |
Air Flow Rate µ min (ANR) *Note1 |
283 |
566 |
833 |
1516 |
1866 |
2800 |
4233 |
6366 |
8500 |
13700 |
At Outlet Pressure Dew Point of 10°C |
Operating Pressure(MPa) |
0.7 |
Inlet Air Temparature( °C) |
35 |
Ambient Temparature( °C) |
25 |
Operating Ranges |
Working Fluid |
Compressed Air |
Inlet Air Temparature( °C) |
5 to 50 |
Inlet Air Pressure(MPa) |
0.15 to 1.0 |
Ambient Temperature( °C) |
2 to 40 (Relative humidity of 85% or less) |
Electrical Specification |
Power Supply Voltage |
Single Phase 230 VAC ± 10% 50Hz |
Operating Current (A) *Note2 |
1.2 |
1.2 |
1.2 |
1.4 |
2.7 |
3.0 |
4.0 |
5.4 |
7.9 |
Power Consumption (W) *Note2 |
180 |
180 |
180 |
208 |
385 |
470 |
760 |
1130 |
1700 |
Circuit Breaker (A) *Note3 |
5 |
10 |
20 |
Condenser |
Air-cooled type |
Refrigerant |
R134A (HFC) |
R407C (HFC) |
Auto Drain |
Float type (normally closed) |
Float type (normally open) |
Port Size |
Rc 3/8 |
Rc 1/2 |
Rc 3/4 |
Rc 1 |
R 1 |
R 1·1/2 |
R2 |
Accessory (kg) |
Hexagon nipple |
|
Weight (kg) |
18 |
22 |
23 |
27 |
28 |
46 |
54 |
62 |
100 |
116 |
Coating Color |
Body panel: White 1 Base: Gray 2 |
Compliant Standards |
EU directive compliant (with CE marking) |
Applicable Compressor kW (Standard) |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
22 |
37 |
55 |
75 |
*Note1: The data for µmin (ANR) refers to the condition of 20 °C, 1 atm. pressure and relative humidity of 65%. |
*Note2: The value is that of under specified condition. |
*Note3: Install GFCI breaker that comes with sensivity of 30mA. |
*Note4: When short period power shortage (including instantly recovered shortage) is recovered. It may take a longer starting period the un-usual starting or may not start due to the protective devices. |
 |
Refrigerant R22 Series IDF Medium - 11D, 11C, 15C, 15C1, 22C, 22C1, 37C, 37C1, 55C, 75C |
|
Model |
IDF11D |
IDF11C |
IDF15C |
IDF15C1 |
IDF22C |
IDF22C1 |
IDF37C |
IDF37C1 |
IDF55C |
IDF75C |
Rated Conditions |
Air Flow Rate µ min (ANR) *Note1 |
50Hz |
1300 |
2050 |
3150 |
5200 |
7650 |
10500 |
60Hz |
- |
1500 |
2400 |
- |
- |
3700 |
- |
6100 |
9000 |
12400 |
Operating Pressure(MPa) |
0.7 |
Inlet Air Temparature( °C) |
40 |
Ambient Temparature( °C) |
32 |
Pressure Dew Point( °C) |
10 |
Operating Ranges |
Working Fluid |
Compressed Air |
Inlet Air Temparature( °C) |
5 to 50 |
Inlet Air Pressure(MPa) |
0.15 to 1.0 |
Ambient Temperature( °C) |
2 to 40 (Relative humidity of 85% or less) |
Electrical Specs |
Power Source |
Single Phase 100/100 to 110VAC(50/60Hz) 220/240VAC(50Hz) 220 to 240VAC(50Hz) |
Three Phase,200/200 to 220VAC(50/60Hz) Single Phase,200,400VAC(50Hz) |
Power Con- sumption (W) |
100 VAC |
50Hz |
- |
320 |
543 |
- |
- |
- |
- |
- |
- |
- |
60Hz |
- |
347 |
662 |
- |
- |
- |
- |
- |
- |
- |
200 VAC |
50Hz |
- |
308 |
561 |
- |
- |
670 |
- |
750 |
1400 |
2100 |
60Hz |
- |
346 |
652 |
- |
- |
800 |
- |
880 |
1750 |
2150 |
220 to 240 VAC |
50Hz |
337 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
220 VAC |
50Hz |
- |
- |
- |
548 |
747 |
- |
830 |
- |
1530 |
2150 |
240 VAC |
50Hz |
- |
- |
- |
570 |
777 |
- |
860 |
- |
1580 |
2200 |
Circuit Breaker (A) *Note2 |
10(for 100VAC), 5(for 200VAC) |
10 |
15 |
Condenser |
Air Cooled |
Refrigerant |
R134a |
R22 |
Air Connection |
Rc 3/4 |
Rc 1 |
Rc 1 1/2 |
Rc 2 |
Drain Connection |
Rc 1/4 |
Auto Drain |
INA-20-41-04 *Note3 |
Weight (kg) |
100 to 200VAC |
- |
47 |
50 |
- |
- |
60 |
- |
72 |
114 |
126 |
220 to 240VAC |
50 |
- |
- |
53 |
60 |
- |
72 |
- |
125 |
135 |
Coating Color |
Munsell 10Y8/0.5 (White) |
Applicable Compressor (screw type) kW |
11 |
15 |
22 |
37 |
55 |
75 |
*Note1: The data for µmin (ANR) refers to the condition of 20 °C, 1 atm. pressure and relative humidity of 65%. |
*Note2: Install a circuit breaker with sensitivity of <=30 mA. |
*Note3: Spare part for auto drain INA-20-41-04 is AD44-x445. |
 |
Refrigerant R407C, R22 Series IDF Large - 120D, 150D, 190D, 240D, 370B |
Model |
IDF120D |
IDF150D |
IDF190D |
IDF240D |
IDF370B*Note4 |
Rated Conditions |
Air Flow Rate*Note5 (m3/min(ANR)) |
50Hz |
20 |
25 |
32 |
43 |
54 |
60Hz |
23 |
30 |
38 |
50 |
65 |
Inlet Air Pressure(MPa) |
0.7 |
Inlet Air Temperature( °C) |
40 |
35 |
Ambient Temperature( °C) |
32 |
Outlet Air Pressure Dew Point( °C) |
10 |
Operating Ranges |
Working Fluid |
Compressed Air |
Inlet Air Temparature( °C) |
5 to 50 |
Inlet Air Pressure(MPa) |
0.15 to 1.0 |
Ambient Temperature(Humidity)( °C) |
2 to 40 (Relative humidity of 85% or less) |
2 to 43 |
Electrical Specifications |
Power Source |
Three Phase 200/220VAC(50/60Hz) Three Phase 380VAC(50Hz) Three Phase 410VAC(50Hz) |
Three Phase 200/220VAC(50/60Hz) Three Phase 380VAC(50Hz) Three Phase 410VAC(50Hz) |
Three Phase 200/220VAC (50/60Hz) |
Power Consumption(W) |
200 AVC |
50Hz |
2.5 |
4.0 |
4.9 |
6.3 |
8.1 |
60Hz |
3.1 |
5.0 |
5.9 |
7.6 |
9.5 |
380AVC 415AVC |
50Hz |
2.1 |
3.3 |
- |
- |
- |
2.2 |
3.4 |
- |
- |
- |
Circuit Breaker (A) |
200 AVC |
30 |
50 |
50 |
60 |
80 |
380 AVC |
15 |
20 |
- |
- |
- |
451 AVC |
Condenser |
Air Cooled |
Water Cooled |
Refrigerant |
R407C |
R22 |
Air Connection |
2 1/2B flange |
3B flange |
4B flange |
6B flange |
Drain Connection (Rc) |
Rc 1/2 |
Rc 3/8 |
Auto Drain |
H 4000-04 |
ADM200-042-8 |
Weight (kg) |
330 |
350 |
450 |
660 |
1100 |
Coating Color |
Body panel: Munsell 10Y8/0.5 (White) Base: Black |
Front panel: Munsell 2.5PB5/8.5 (Blue) Other panels (Except base): Munsell N-B (White) |
Applicable Compressor kW |
120 |
150 |
190 |
240 |
370 |
*Note4: This is made to order. |
*Note5: The data for µmin (ANR) refers to the condition of 20 °C, 1 atm. pressure and relative humidity of 65%. |
Accessories (Option) |
Description |
Features |
Specifications |
Applicable Dryer |
Dimensions |
Transformer Separately Installed
 |
This is for power and voltage supply other than standard. |
Max. ambient temparature 40°C (Relative humidity 85% or less) |
All models |
14-17-30 |
Base Integrated with Transformer
 |
Avoid decreasing of air dryer performance even in dusty atmosphere. |
|
IDU3D to 15C IDF4D to 75C |
14-17-30 |
Dust Proof Filter Set
 |
This is the base for integrating the transformer and air dryer. |
Max. ambient temparature 40°C |
IDU3D to 75C IDF1D to 75C |
14-17-30 |
Bypass Piping Set
 |
Easy bypass piping (connect this set to air dryer), realizing substantial reduction of man-hours at the site. |
Max. operating pressure 1.0MPa Max. operating temperature 60°C |
IDU3D to 75C IDF1D to 75C |
14-17-31 |
|