DRYERS CKD - OVERVIEW


Ecological compact dryer GX3100 | GX5100 Series
New refrigerant R-407C to prevent ozone destruction is used in CKD refrigerating type dryer GX3000/5000 Series. Introducitn the all new GX Series!
  • Stainless steel heat exchanger compatible with oil free compressed air
    • Outstanding corrosion resisitance
      GX3108 | GX5103 to 5108
      The stainless steel plate heat exchanger provides outstanding corrosion-resistant, preventing refrigerant leaks and rust formation.
      GX3111 to 3137 | GX5111 to 5137
      A stainless steel vessel is used, and refrigerant piping is configured from spiral fin tubing free of brazed sections.
    • All models compatible with high pressure
      Standard specifications, max. working pressure 1.6MPa, are provided for all models.

  • Ensuring reliability with forced drain
    • Eliminating problems during drainage
      Drainage is forcibly ejected by the dryer’s air pressure, leaving pipes unclogged. Reliability is greatly improved using a direct-acting solenoid valve.
    • Air loss prevention
      GX3111 to 3137 | GX5111 to 5137

      Drainage discharge time is controlled based on inlet air temperature. Air loss is prevented. Solenoid valve operating frequently drops with inlet air temperature, extending solenoid volve life.

  • Highly efficient daily inspections
    • Operational status of the dryer is easily checked by the electronic dew point monitor in the operation panel.
    • Central control in the plant is possible. (Option)
      Centralized control is realized at the factory using remote operation and by reading out run/error signal output.(*GX3108 and GX5103 to 5108 allow output of running signal only.)
    • Dust filter equipped
      Dust filter for the capacitor is provided as standard. Mounting or removing the filter is also easy.
    • Easy to remove front panel (tool not required)
    • This is available for various power voltage (option)
      The built-in transformer eliminates the need for a standalone or external transformer, free extra space.
SPECIFICATION

Refrigerating Type Air Dryer GX3100 Series
Applicable Air Compressor: 7.5kW, 11kW, 15kW, 22kW and 37kW
Model GX3108 GX3111 GX3115 GX3122 GX3137
Applicable Air Compressor(kW) 7.5 11 15 22 37
Specified
Range
Working Fluid Compressed Air
Inlet Air Temperature( °C) 5 to 50
Inlet Air Pressure(MPa) 0.2 to 1.6
Ambient Temperature( °C) 2 to 43
Rated Treating Flow Rate (min3/min(ANR)*Note1) 50/60Hz 1.20/1.30 1.65/1.82 2.80/3.10 3.90/4.30 6.60/7.30
Inlet Air Temperature( °C) 35
Inlet Air Pressure(MPa) 0.7
Ambient Temperature( °C) 32
Performance Outlet Air Pressure Dew Point ( °C) 10
Pressure Drop (MPa) *Note2 50/60Hz 0.023/0.027 0.005/0.006 0.014/0.017 0.0026/0.0032 0.007/0.008
Power Supply Single Phase
100/100-110VAC
50/60Hz
Single Phase 200/200-220VAC
50/60Hz
Three Phase
200/200-220VAC
50/60Hz
Single Phase
200/200-220VAC
50/60Hz
Electric
Specifications
Power Consumption (kW) 50/60Hz 0.41/0.50 1.16/1.29 1.17/1.32 1.19/1.36 1.53/1.89
Operating Current(at 100V)A 50/60Hz 4.5/4.9
Operating Current(at 200V)A 50/60Hz 2.4/2.5 6.5/6.7 6.6/6.8 6.7/7.0 5.4/6.0
Starting Current(at 100V)A 50/60Hz 17.6/16.3
Starting Current(at 200V)A 50/60Hz 9.6/8.9 26.7/24.5 26.7/24.5 26.7/24.5 27.8/24.7
Refrigerant R-407C
Air Inlet/Outlet Port Size RC 3/4 RC 1 RC 1 R1 1/2 R1 1/2
Drain Port Size RC 1/4 RC 1/4 RC 1/4 RC 1/4 RC 1/4
Product Weight(kg) 40 65 65 83 102
Exhaust Heat(kW) 50/60Hz 0.71/0.79 1.7/1.9 2.1/2.4 2.2/2.4 3.3/3.8
*Note1: ANR indicates status at 20 °C atmospheric pressure and 65% relative humidity.
*Note2: Pressure drops are typically and not guaranteed.


Refrigerating Type Air Dryer GX5100 Series
Applicable Air Compressor: 2.2kW, 3.7kW, 5.5kW, 7.5kW, 11kW, 15kW, 22kW and 37kW
Model GX5103 GX5104 GX5106 GX5108 GX5111 GX5115 GX5122 GX5137
Applicable Air Compressor(kW) to 2.2 3.7 5.5 7.5 11 15 22 37
Specified
Range
Working Fluid Compressed Air
Inlet Air Temperature (°C)*Note3 5 to 80
Inlet Air Pressure (MPa) 0.2 to 1.6
Ambient Temperature ( °C)*Note3 2 to 43
Rated Treating Flow Rate (min3/min (ANR)*Note1) 50/60Hz 0.31/0.35 0.50/0.55 0.74/0.81 1.20/1.30 1.65/1.82 2.80/3.10 3.90/4.30 6.60/7.30
Inlet Air Temperature ( °C) 55
Inlet Air Pressure (MPa) 0.7
Ambient Temperature ( °C) 32
Performance Outlet Air Pressure Dew Point ( °C) 10
Pressure Drop (MPa) *Note2 50/60Hz 0.009/
0.011
0.023/
0.027
0.009/
0.011
0.023/
0.027
0.005/
0.006
0.015/
0.018
0.0026/
0.0032
0.008/
0.009
Power Supply Single Phase 100/100-110VAC
50/60Hz
Single Phase
200/200 - 220VAC
50/60Hz
Three Phase 200/200 - 220VAC
50/60Hz
Single Phase 200/200 - 220VAC
50/60Hz
Electric
Specifications
Power Consumption (kW) 50/60Hz 0.25/0.26 0.25/0.26 0.42/0.49 0.43/0.50 1.20/1.35 1.69/2.06 1.61/1.98 2.51/3.11
Operating Current(at 100V)A 50/60Hz 3.2/2.7 3.2/2.8 4.7/5.0 4.7/5.0
Operating Current(at 200V)A 50/60Hz 1.4/1.3 1.4/1.4 2.4/2.4 2.4/2.5 6.7/7.0 5.9/6.5 5.9/6.2 9.0/10.2
Starting Current(at 100V)A 50/60Hz 8.6/8.1 8.6/8.1 17.6/16.3 17.6/16.3
Starting Current(at 200V)A 50/60Hz 4.1/3.8 4.1/3.8 9.6/8.9 9.6/8.9 26.7/24.5 27.8/24.7 27.8/24.7 68.0/60.0
Refrigerant R-407C
Air Inlet/Outlet Port Size RC 3/8 RC 3/8 RC 3/4 RC 3/4 RC 1 RC 1 R1 1/2 R1 1/2
Drain Port Size RC 1/4 RC 1/4 RC 1/4 RC 1/4 RC 1/4 RC 1/4 RC 1/4 RC 1/4
Product Weight(kg) 28 28 40 40 65 76 102 128
Exhaust Heat(kW) 50/60Hz 0.44/0.49 0.59/0.64 0.94/1.04 1.3/1.4 2.6/2.9 4.0/4.7 4.4/5.1 7.2/8.3
*Note1: ANR indicates status at 20 °C atmospheric pressure and 65% relative humidity.
*Note2: Pressure drops are typically and not guaranteed.
*Note3: If inlet air temperature and ambient temperature are both at a maximum (80 °C and 43 °C), use the rated flow cannot be guaranteed. Continuing operation will shorten product life. Refer to seperate specifications for details on the working range.