FILTER CKD - OVERVIEW


The maximum working pressure has been increased from that of conventional air filters, enabling use with medium-pressure specifications such as medium-pressure compressors.

    Features:
  • Max. working pressure: 1.6 MPa
  • A great variety of series
    Developing filter and oil mist filter
SPECIFICATION

Air Filter Medium Pressure Type
FM3000/FM4000/FM6000/FM8000 Series
Medium pressure specifications for F3000 to 8000 Series
Model FM3000 FM4000 FM6000 FM8000
Appearance
Working Fluid Compressed Air
Max. Working Pressure(MPa) 1.6
Withstanding Pressure(MPa) 2.4
Ambient Temperature( ° C) -5 to 60 ( no freezing )
Fluid Temperature( ° C) 5 to 60
Filtration Rating( ·m) 5 or 0.3
Drain Capacity(cm3) 45 80 80 80 *Note1
Port Size 1/4, 3/8 1/4, 3/8, 1/2 3/4, 1 3/4, 1
Product Weight(kg) 0.5 0.55 1.0 1.26
*Note1: Drainage accumulates up to 170 cm3 only with the manual drain cock.


Oil Mist Filter Medium Pressure Type
MM3000/MM4000/MM6000/MM8000 Series
Medium pressure specifications for M3000 to 8000 Series
Model MM3000 MM4000 MM6000 MM8000
Appearance
Working Fluid Compressed Air
Max. Working Pressure(MPa) 0.1 to 1.6
Withstanding Pressure(MPa) 2.4
Drain Capacity(cm3) 45 80 80 80
Port Size 1/4, 3/8 1/4, 3/8, 1/2 3/4, 1 3/4, 1
Product Weight(kg) 0.35 0.55 1.0 1.48
Mantel Option Name Blank (M Type) S (S Type) X (X Type)
Treating Flow Rate L/min (ANR)
Primary side pressure 1.4MPa
Pressure Drop 0.01MPa
MM3000 490 610 610
MM4000 1130 1370 1370
MM6000 1740 1920 1920
MM8000 3560 3980 3980
Ambient Temperature( ° C) -5 to 60 (no freezing) -5 to 30 (no freezing)
Fluid Temperature( ° C) 5 to 60 5 to 30
Filtration Rating( ·m) 0.01 (nominal) 0.03 Absorption by activated charcoal
*Note3
Secondary Side Oil Concentration(mg/m3) 0.01 or less
*Note1, Note2
0.5 or less
*Note1
0.003 or less
*Note1, Note4
Mantle (Element) Change One year (6000 hours) or pressure drop 0.1MPa *Note5
*Note1: At primary side oil concentration 30mg/m3, inlet air temperature 21 °C.
*Note2: Install an S oil mist filter as a pre-filter on the preliminary side to prevent early clogging.
*Note3: Install an F Series air filter or M Series or M or S oil mist filter on the secondary side to prevent active
              carbon particles from reaching the secondary side.
*Note4: When oil mist filter (M type of M series) is installed on the primary side.
*Note5: X mantle (element) replacement is determined by odor concentration in compressed air, and cannot be
              clearly indicated.
              Time from initial installation to when an oil odor is noted is the effective deodorization time.
              Replace the mantle (element) regularly during this time.
              The primary air temperature must be 30 °C or less. Deodorizing decreases if the temperature is high,
              so provide measures to dissipate heat.